| Symptom / Error |
FRU / Action in Sequence |
10X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt failure.
104: Protected mode failure.
105: Last 8042 command not accepted.
107: NMI test failure.
108: Timer bus test failure.
109: Low meg-chip select test. |
1. System board |
| 161 |
1. Go to "Checking the Backup Battery" (Dead battery.) on page 10.
2. Backup battery
3. System board |
| 163 |
1. Set time and date.
(Time and Date was not set.)
2. System board |
173
(Configuration data was lost.) |
1. Select OK in the error screen; then set the time and date.
2. Backup battery
3. System board |
174
(Configuration error:Perform "Checking the Installed Devices List" on page 24 before changing any FRUs.) |
1. Check Device Configuration.
2. Hard disk drive
3. System board |
184
(POP check sum error.) |
1. Reset the POP (power-on password) in Easy-Setup. |
190
(Depleted battery pack was installed when on page 9. the power was on.)
|
1. Go to "Checking the Battery Pack" |
191XX
(PM initialization error.) |
1. System board |
195
(The configuration read from the hibernation area does not match the actual configuration) |
1. Check if the configuration was changed. For example, check if the DIMM is added. |
196
(Read error occurred in the hibernation area of the HDD.) |
1. Run the hard disk drive test.
2. Hard disk drive |
| 1XX |
1. System board |
2XX
201: Memory data error.
202: Memory line error 00-15
203: Memory line error 16-23.
205: Memory test failure on on-board memory.
221: ROM to RAM remap error. |
1. Go to "Memory Checkout"
2. DIMM
3. System board |
301, 303, 304, 305, 3XX
(301: Keyboard error.) |
1. Go to "Keyboard/Auxiliary Input Device Checkout" on page 6.
2. Keyboard
3. External numeric keypad
4. External keyboard
5. Keyboard/mouse cable
6. Subcard
7. System board |
601, 6XX
(601: Diskette drive or controller error.) |
1. Go to "Diskette Drive Test"
2. FDD assembly
3. Diskette
4. System board |
602
(Diskette read error.) |
1. Go to "Diskette Drive Test"
2. Diskette
3. FDD assembly |
604
(Unacceptable ID was read from the diskette drive.) |
1. Go to "Diskette Drive Test"
2. FDD assembly
3. System board |
11XX
1101: Serial_A test failure. |
1. Serial device
2. Communication cable
3. System board |
12XX
1201: Serial_B test failure. |
1. System board (Infrared) |
17XX
1701: Hard disk controller failure.
1780, 1790: Hard disk 0 error.
1781, 1791: Hard disk 1 error. |
1. Hard disk drive
2. System board |
24XX
(2401: System board video error.) |
1. System board |
808X
8081: PCMCIA presence test failure. (PCMCIA revision number also checked.)
8082: PCMCIA register test failure. |
1. PCMCIA slot assembly
2. PCMCIA device
3. System board |
860X
(Pointing device error when TrackPoint III is disabled.)
8601: System bus error-8042 mouse
interface.
8602: External mouse error.
8603: System bus error or mouse
error. |
1. External mouse
2. External keyboard
3. System board |
861X
(Pointing device error when TrackPoint III is enabled.)
8611: System bus error-I/F between
8042 and IPDC.
8612: TrackPoint error.
8613: System board or TrackPoint error. |
1. Reseat the keyboard cables.
2. Keyboard
3. External mouse
4. System board |
I9990301
I9990302
I9990305
I9990301: Hard disk error.
I9990302: Invalid hard disk boot
I9990305: No bootable device. |
1. Check that the operating system is installed in the HDD. If not, install the operating system.
2. Reseat the boot device.
3. Check the startup sequence for the record. correct boot device.
4. Check that the operating system has no failure and is installed correctly. |
I9990303
(Bank-2 flash ROM check sum error.) |
1. System board |
| Other codes, not in this list |
1. Go to "Undetermined Problems" |